{"id":6960,"date":"2025-05-27T11:29:23","date_gmt":"2025-05-27T09:29:23","guid":{"rendered":"https:\/\/www.siphoniker.at\/?p=6960"},"modified":"2025-06-05T12:01:16","modified_gmt":"2025-06-05T10:01:16","slug":"guidelines-for-the-dimensioning-of-drainage-of-roof-balcony-and-terrace-areas","status":"publish","type":"post","link":"https:\/\/www.siphoniker.at\/en\/guidelines-for-the-dimensioning-of-drainage-of-roof-balcony-and-terrace-areas\/","title":{"rendered":"Guidelines for the dimensioning of drainage of roof, balcony and terrace areas"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"6960\" class=\"elementor elementor-6960 elementor-6303\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8105334 e-flex e-con-boxed e-con e-parent\" data-id=\"8105334\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b52cb56 elementor-widget elementor-widget-text-editor\" data-id=\"b52cb56\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>This guide provides a comprehensive introduction to the technical requirements and calculations for the dimensioning of drainage systems for roofs, balconies and terraces. The various drainage solutions and their specific advantages and disadvantages are considered in order to ensure reliable and standard-compliant planning. The aim is to use efficient drainage solutions to prevent water damage and flooding and to ensure the long-term functionality and safety of the building.<\/strong><\/p><p>Heavy rainfall events, which can lead to flooding and damage of buildings, are referred to as extreme weather events, but large amounts of rainfall that occurs locally within a short period of time have almost become the norm. Climate change is often blamed for this &#8211; a reality that we have to come to terms with whether we like it or not. This makes it all the more important to carefully plan and implement the rainwater drainage of a building &#8211; especially for roofs, balconies and terraces &#8211; in accordance with standards in order to avoid water damage.\u00a0<\/p><p>Proof of standard-compliant planning of a rainwater system requires a project-specific hydraulic calculation and comprehensive documentation.<\/p><h3>Rainwater drainage basics<\/h3><p>Before a concrete example of interpretation can be considered, it is essential to know some basics and distinctions.<\/p><p><strong>What does a roof drainage system consist of?<br \/><\/strong>The most important components of a roof drainage system are<\/p><ul><li>Roof gutters or roof drains (these must be securely integrated into the building waterproofing)<\/li><li>drainage pipes<\/li><li>Pipe fastening system<\/li><li>Any necessary condensation water insulation of the rainwater pipes<\/li><li>Measures for fire, sound and noise protection.<\/li><\/ul><p>\u00a0<\/p><p>The components selected depend largely on the type of the drainage system chosen. The basic drainage systems available and how they are differentiated will now be discussed.<\/p><h3>Differentiation according to drainage method<\/h3><p>In rainwater drainage, a basic distinction is made between 2 systems. Both systems differ significantly in terms of pipe layout and pipe dimensioning.<\/p><p><strong>Gravity drainage (gravity principle) <br \/><\/strong>In rainwater drainage, a basic distinction is made between 2 systems. Both systems differ significantly in terms of pipe layout and pipe dimensioning.<\/p><p>During planning, it is assumed that the horizontal rainwater pipes are approximately 70% full of water and the vertical downpipes approximately 33% full of water. These values \u200b\u200bhelp to correctly determine the required pipe dimensions.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-515c24e e-flex e-con-boxed e-con e-parent\" data-id=\"515c24e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1245776 elementor-widget elementor-widget-image\" data-id=\"1245776\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"566\" src=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb01_Schema-Freispiegelentwasserung-1024x724.png\" class=\"attachment-large size-large wp-image-6469\" alt=\"\" srcset=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb01_Schema-Freispiegelentwasserung-1024x724.png 1024w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb01_Schema-Freispiegelentwasserung-300x212.png 300w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb01_Schema-Freispiegelentwasserung-768x543.png 768w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb01_Schema-Freispiegelentwasserung-1536x1086.png 1536w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb01_Schema-Freispiegelentwasserung-2048x1448.png 2048w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb01_Schema-Freispiegelentwasserung-1920x1357.png 1920w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 1: Scheme of gravity drainage<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2974fd8 e-flex e-con-boxed e-con e-parent\" data-id=\"2974fd8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-690c02e elementor-widget elementor-widget-spacer\" data-id=\"690c02e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5524aaa elementor-widget elementor-widget-text-editor\" data-id=\"5524aaa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Vacuum \/ under pressure drainage (suction principle)<br \/><\/strong>In contrast, <strong>negative\/under pressure or siphonic roof drainage<\/strong> works according to the principle of full filling. The rainwater is literally sucked off the roof. With small amounts of rainfall, the suction effect only occurs sporadically or not at all, so that the advantages of this system are only fully realised when there is sufficient rainfall. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f669c28 e-flex e-con-boxed e-con e-parent\" data-id=\"f669c28\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8c8ee3d elementor-widget elementor-widget-image\" data-id=\"8c8ee3d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"566\" src=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb02_Schema-Unterdruckentwasserung-1024x724.png\" class=\"attachment-large size-large wp-image-6480\" alt=\"\" srcset=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb02_Schema-Unterdruckentwasserung-1024x724.png 1024w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb02_Schema-Unterdruckentwasserung-300x212.png 300w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb02_Schema-Unterdruckentwasserung-768x543.png 768w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb02_Schema-Unterdruckentwasserung-1536x1086.png 1536w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb02_Schema-Unterdruckentwasserung-2048x1448.png 2048w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb02_Schema-Unterdruckentwasserung-1920x1357.png 1920w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 2: Scheme of negative pressure drainage<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a79ac65 e-flex e-con-boxed e-con e-parent\" data-id=\"a79ac65\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ba021bd elementor-widget elementor-widget-text-editor\" data-id=\"ba021bd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>When to use which system?<\/h3><p>Today, large, wide-span roof areas are preferably drained using the negative pressure principle, as this system requires less material and labour. Thanks to the slope-free pipe routing under the roof structure, which is permitted with this system, negative pressure drainage offers a space-saving solution, particularly in high-rise warehouses. The planning and calculation of such systems is carried out almost exclusively by the respective system provider.<\/p><p>Not every roof area is suitable for negative pressure drainage, such as roof terraces, balconies or roofs of residential buildings. Conventional drainage may also be the better choice for warehouses or production halls in certain cases.<\/p><p>What are the arguments in favour of conventional\/free-flow drainage?<\/p><ul><li>The system can be designed by the planner himself in simple steps with the help of EN1253-2 and EN12056-3. There is no dependence on the system provider!<\/li><li>In the case of roof structures with a low runoff coefficient, such as green roofs, the rainwater is delayed and released to the drain in smaller quantities, so that full filling cannot be achieved. In this case, a system with pipes laid on a slope makes more sense<\/li><li>If the water volume is low and the pipes are laid horizontally without a gradient (negative pressure drainage), the risk of blockages increases as the self-cleaning effect is not achieved due to the lack of full filling. Here too, conventional drainage makes more sense<\/li><\/ul><p>\u00a0<\/p><p>Which of the two systems ultimately makes the most sense from an economic and technical point of view should always be checked by the planner on a case-by-case basis.<\/p><p>As the design of negative pressure drainage always depends on the system or manufacturer and therefore no generalised statements can be made about planning and implementation, this is not covered in this guide. In the following, the design of gravity drainage will be analysed in detail.<\/p><p>For gravity drainage, however, two further distinctions must be made. One differentiation according to the pipework scheme and one according to the connection method.<\/p><h3>Differentiation according to pipe layout<\/h3><p>In conventional gravity drainage, an additional important distinguishing feature is the piping layout.<\/p><p><strong>Individual piping connection, closed system<br \/><\/strong>Each roof drain is individually piped to the base pipe in the same dimension without interruption.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-69333b3 e-flex e-con-boxed e-con e-parent\" data-id=\"69333b3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d6b1699 elementor-widget elementor-widget-image\" data-id=\"d6b1699\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"566\" src=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb03_Schema-geschlossenes-System-1024x724.png\" class=\"attachment-large size-large wp-image-6488\" alt=\"\" srcset=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb03_Schema-geschlossenes-System-1024x724.png 1024w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb03_Schema-geschlossenes-System-300x212.png 300w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb03_Schema-geschlossenes-System-768x543.png 768w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb03_Schema-geschlossenes-System-1536x1086.png 1536w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb03_Schema-geschlossenes-System-2048x1448.png 2048w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb03_Schema-geschlossenes-System-1920x1357.png 1920w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 3: Schematic of closed system (individual piping)<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b3ecccd e-flex e-con-boxed e-con e-parent\" data-id=\"b3ecccd\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f3013d1 elementor-widget elementor-widget-text-editor\" data-id=\"f3013d1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Closed system means that the roof outlet is tightly connected to the rainwater pipe as shown in Figure 4. The roof outlet and the pipe must have the same dimensions throughout.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3bd3c5d e-flex e-con-boxed e-con e-parent\" data-id=\"3bd3c5d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ebdcc9f elementor-widget elementor-widget-image\" data-id=\"ebdcc9f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"566\" src=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb04_Detail-geschlossenes-System_korr-1024x724.png\" class=\"attachment-large size-large wp-image-7121\" alt=\"\" srcset=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb04_Detail-geschlossenes-System_korr-1024x724.png 1024w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb04_Detail-geschlossenes-System_korr-300x212.png 300w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb04_Detail-geschlossenes-System_korr-768x543.png 768w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb04_Detail-geschlossenes-System_korr-1536x1086.png 1536w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb04_Detail-geschlossenes-System_korr-2048x1448.png 2048w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb04_Detail-geschlossenes-System_korr-1920x1357.png 1920w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 4 Detail: Closed system<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7bb5e3a e-flex e-con-boxed e-con e-parent\" data-id=\"7bb5e3a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e6b711b elementor-widget elementor-widget-spacer\" data-id=\"e6b711b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a272477 elementor-widget elementor-widget-text-editor\" data-id=\"a272477\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Collective piping, open system<br \/><\/strong>Several roof drains are connected to the ground pipe by means of a collector and downpipe.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-792cfca e-flex e-con-boxed e-con e-parent\" data-id=\"792cfca\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-95de8f2 elementor-widget elementor-widget-image\" data-id=\"95de8f2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"566\" src=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb05_Schema-offenes-System-mit-Kanal-1024x724.png\" class=\"attachment-large size-large wp-image-6504\" alt=\"\" srcset=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb05_Schema-offenes-System-mit-Kanal-1024x724.png 1024w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb05_Schema-offenes-System-mit-Kanal-300x212.png 300w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb05_Schema-offenes-System-mit-Kanal-768x543.png 768w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb05_Schema-offenes-System-mit-Kanal-1536x1086.png 1536w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb05_Schema-offenes-System-mit-Kanal-2048x1448.png 2048w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb05_Schema-offenes-System-mit-Kanal-1920x1357.png 1920w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 5: Open system, collective piping<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-eb6eb57 e-flex e-con-boxed e-con e-parent\" data-id=\"eb6eb57\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e0e2058 elementor-widget elementor-widget-spacer\" data-id=\"e0e2058\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b1066bd elementor-widget elementor-widget-text-editor\" data-id=\"b1066bd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>An open system means that the roof outlet (as shown in Figure 2) is connected to a horizontal pipe and connected to a larger downpipe that is open on both sides.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2ebdc33 e-flex e-con-boxed e-con e-parent\" data-id=\"2ebdc33\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a56e7d3 elementor-widget elementor-widget-image\" data-id=\"a56e7d3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"566\" src=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb06_Detail-offenes-System-1024x724.png\" class=\"attachment-large size-large wp-image-6512\" alt=\"\" srcset=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb06_Detail-offenes-System-1024x724.png 1024w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb06_Detail-offenes-System-300x212.png 300w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb06_Detail-offenes-System-768x543.png 768w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb06_Detail-offenes-System-1536x1086.png 1536w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb06_Detail-offenes-System-2048x1448.png 2048w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb06_Detail-offenes-System-1920x1357.png 1920w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 6 Detail: Open system<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-aef6e9b e-flex e-con-boxed e-con e-parent\" data-id=\"aef6e9b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6841185 elementor-widget elementor-widget-text-editor\" data-id=\"6841185\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In principle, it can be assumed that a higher drainage capacity is achieved in closed systems. This is due to the fact that the suction effect is boosted by the pipe being connected in the same dimension throughout.<\/p><h3>Guidelines for planning and implementation<\/h3><p>Before dimensioning and design can begin, there is some basic information and data on the construction project that must be determined and specified.<\/p><p>This includes:<\/p><ul><li>Detailed building plans with areas to be drained<\/li><li>Roof structure, waterproofing and materials used<\/li><li>Permitted static loads to determine the maximum permissible water accumulation height<\/li><li>Address or postal code of the building project (important for the calculation rainfall rate)<\/li><li>Piping layout<ul><li>Individual or collective connection piping<\/li><li>Closed or open system<\/li><\/ul><\/li><\/ul><p>\u00a0<\/p><p>Based on this information, the calculated rainfall rate, the runoff coefficient and the drainage capacity of the roof drains used must then be determined.<\/p><p><strong>Calculation rainfall rate (r)<br \/><\/strong>The first step in dimensioning the drainage system is to determine the calculation rainfall rate <strong>r<\/strong>. This is the basis for every drainage system.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-917cdc2 e-flex e-con-boxed e-con e-parent\" data-id=\"917cdc2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fb06dae elementor-widget elementor-widget-image\" data-id=\"fb06dae\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"384\" src=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb07-1024x491.png\" class=\"attachment-large size-large wp-image-6520\" alt=\"\" srcset=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb07-1024x491.png 1024w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb07-300x144.png 300w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb07-768x368.png 768w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb07.png 1500w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 7: Austrian grid for rainfall measurement<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c040157 e-flex e-con-boxed e-con e-parent\" data-id=\"c040157\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d0b084d elementor-widget elementor-widget-spacer\" data-id=\"d0b084d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ec5f3fd elementor-widget elementor-widget-text-editor\" data-id=\"ec5f3fd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The roof drainage is to be dimensioned for the 5-minute rainfall event with a 5-year return frequency. As a rule, the design rainfall for the respective location is to be taken from the data sets of the <a href=\"https:\/\/ehyd.gv.at\/\" target=\"_blank\" rel=\"noopener\">Federal Ministry of Agriculture, Forestry, Environment and Water Management<\/a> and then converted to a design rainfall rate in l\/(s &#8211; ha).<\/p><p>The minimum design rainfall for roof areas and property areas is set at 300 litres\/(s &#8211; ha). Roof drainage is dimensioned in accordance with \u00d6NORM EN 12056-3:2000, section 4.1. This values can differentiate in specific regions and countries.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ccd7ec0 elementor-widget elementor-widget-spacer\" data-id=\"ccd7ec0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-6598841 e-flex e-con-boxed e-con e-parent\" data-id=\"6598841\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-821a61a elementor-widget elementor-widget-image\" data-id=\"821a61a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"698\" src=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Tabelle_1_EN-1024x894.jpg\" class=\"attachment-large size-large wp-image-7205\" alt=\"\" srcset=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Tabelle_1_EN-1024x894.jpg 1024w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Tabelle_1_EN-300x262.jpg 300w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Tabelle_1_EN-768x671.jpg 768w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Tabelle_1_EN-1536x1341.jpg 1536w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Tabelle_1_EN-2048x1788.jpg 2048w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Tabelle_1_EN-1920x1677.jpg 1920w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 8: 5-minute rainfall rate for the five-year rainfall event in Fischamend (Austria)<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9fb58d0 e-flex e-con-boxed e-con e-parent\" data-id=\"9fb58d0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b52ce29 elementor-widget elementor-widget-spacer\" data-id=\"b52ce29\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-032789c elementor-widget elementor-widget-text-editor\" data-id=\"032789c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Drainage coefficient (C)<br \/><\/strong>Next, the drainage coefficient C must be determined. The drainage coefficient is the ratio between the amount of rain that currently falls on the drainage area and the amount that is actually fed to the drain. The surface quality of the roof surface plays a significant role here. A green roof surface with a drainage coefficient of 0.3, for example, reduces rainwater runoff by about two thirds.<\/p><p><strong>According to \u00d6NORM B 2501, the following values apply:<\/strong><\/p><ul><li>C = 1,0 for sheet metal roofs, roofs with tile covering, sealed concrete surfaces, foil roofs, paved surfaces with grouted joints, sealed roofs without ballast<\/li><li>C = 0,8 for gravel roofs, gravel paths, paved areas without grouting and extensive green roofs with a layer thickness of no more than 8 cm<\/li><li>C = 0,5 for reduced extensive greening with a layer thickness of more than 8 cm<\/li><li>C = 0,3 for extensive and intensive greening with a layer thickness of 10 cm or more<\/li><li>C = 0,1 for intensive greening with a layer thickness of 25 cm or more<\/li><\/ul><p>\u00a0<\/p><p><strong>Rainwater drainage (Q)<br \/><\/strong>The rainwater quantity <strong>Q<\/strong> is calculated from the size of the area to be drained <strong>A<\/strong>, the relevant rainfall rate <strong>r<\/strong> and the drainage coefficient <strong>C<\/strong> and is calculated using the following formula:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-94a3c48 e-flex e-con-boxed e-con e-parent\" data-id=\"94a3c48\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8d029a5 elementor-widget elementor-widget-image\" data-id=\"8d029a5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"153\" height=\"49\" src=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Formel_0.png\" class=\"attachment-large size-large wp-image-6353\" alt=\"\" srcset=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Formel_0.png 153w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Formel_0-150x49.png 150w\" sizes=\"(max-width: 153px) 100vw, 153px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4cbaeb7 e-flex e-con-boxed e-con e-parent\" data-id=\"4cbaeb7\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b850870 elementor-widget elementor-widget-spacer\" data-id=\"b850870\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d16e9d6 elementor-widget elementor-widget-text-editor\" data-id=\"d16e9d6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>This stands for:<\/p><ul><li>Q for the rainwater runoff in litres per second (l\/s)<\/li><li>r for the design rainfall in litres per second and hectare (l\/s-ha)<\/li><li>A for the effective roof area in square metres (m\u00b2)<\/li><li>C for the drainage coefficient, which takes into account the retention or delay caused by the roof surface<\/li><\/ul><p>\u00a0<\/p><p>This calculation indicates the amount of water that the drainage system must be able to reliably discharge per second in order to ensure standard-compliant drainage.<\/p><p><strong>Drainage capacity of the roof drains<\/strong><br \/>According to EN1253-2, manufacturers of roof and attic drains are obliged to display the drainage values in a table or diagram depending on the height above the sealing flange.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-658887e e-flex e-con-boxed e-con e-parent\" data-id=\"658887e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e396cc9 elementor-widget elementor-widget-spacer\" data-id=\"e396cc9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6d55517 elementor-widget elementor-widget-image\" data-id=\"6d55517\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"242\" src=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb09_EN-1024x310.jpg\" class=\"attachment-large size-large wp-image-6979\" alt=\"\" srcset=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb09_EN-1024x310.jpg 1024w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb09_EN-300x91.jpg 300w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb09_EN-768x233.jpg 768w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb09_EN-1536x465.jpg 1536w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb09_EN-2048x621.jpg 2048w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb09_EN-1920x582.jpg 1920w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 9: Table of drainage capacities tested according to EN 12-53 point 5.5.2.1 on 3m downpipe (i.e. closed system) <\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-84fed5c e-flex e-con-boxed e-con e-parent\" data-id=\"84fed5c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6e600b5 elementor-widget elementor-widget-spacer\" data-id=\"6e600b5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-de62ccc elementor-widget elementor-widget-text-editor\" data-id=\"de62ccc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The drainage performance depends on whether the system used is an open or closed system. It is therefore important to ask the manufacturer under which test criteria the performance of the respective product is tested.<\/p><h3>Calculation examples<\/h3><p>Now that the basic principles of roof drainage have been explained, the practical application follows: the dimensioning of the drainage systems. Depending on the type of system &#8211; open or closed, individual or collective connection &#8211; the calculation approaches differ.<\/p><p>The closed system with collective connection pipework corresponds to the negative pressure principle. As this is dependent on the system and the manufacturer&#8217;s specifications, it will not be discussed further in this guide.<\/p><p>In the following, an example of a roof with two different systems will be calculated: One as a closed system with individual connection piping and one as an open system with collective piping.<\/p><p><strong>Initial data<br \/><\/strong>An 800m\u00b2 flat foil roof with a gradient in one direction is being constructed in Fischamend in the district of Bruck an der Leitha (Austria).<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5d8eebe e-flex e-con-boxed e-con e-parent\" data-id=\"5d8eebe\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3f34a74 elementor-widget elementor-widget-image\" data-id=\"3f34a74\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/elementor\/thumbs\/Abb10_Dachflache-mod-r64oipoz97m7ea9jkjsm1vbwdose8iq0659oolm0ao.jpg\" title=\"Abb10_Dachfl\u00e4che mod\" alt=\"Abbildung 10: Flachdach mit in einer Richtung ausgelegtem Gef\u00e4lle\" loading=\"lazy\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 10: Flat roof with slope designed in one direction<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-bf32117 e-flex e-con-boxed e-con e-parent\" data-id=\"bf32117\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e22fe7a elementor-widget elementor-widget-spacer\" data-id=\"e22fe7a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fc8929b elementor-widget elementor-widget-text-editor\" data-id=\"fc8929b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Regardless of the system selected, the roof area <strong>A<\/strong>, the calculation rainfall rate <strong>r<\/strong>, the drainage coefficient <strong>C<\/strong> &amp; the rainfall <strong>Q<\/strong> can now be determined from this information:<\/p><p><strong><em>A<\/em><\/strong> = Roof area 800 m\u00b2<\/p><p>The 5-minute design rainfall rate r for the five-year rainfall event is taken from the <a href=\"https:\/\/ehyd.gv.at\/\" target=\"_blank\" rel=\"noopener\">hydrographic online service<\/a> as described above (see Figure 4) and converted to litres per second:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-92c601b e-flex e-con-boxed e-con e-parent\" data-id=\"92c601b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a5b9085 elementor-widget elementor-widget-image\" data-id=\"a5b9085\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"436\" height=\"67\" src=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Formel_1_korr3.jpg\" class=\"attachment-large size-large wp-image-7320\" alt=\"\" srcset=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Formel_1_korr3.jpg 436w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Formel_1_korr3-300x46.jpg 300w\" sizes=\"(max-width: 436px) 100vw, 436px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-40d453c e-flex e-con-boxed e-con e-parent\" data-id=\"40d453c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-890a628 elementor-widget elementor-widget-text-editor\" data-id=\"890a628\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The drainage coefficient <strong>C<\/strong> for foil roofs is 1:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-8d9e11a e-flex e-con-boxed e-con e-parent\" data-id=\"8d9e11a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9a0415c elementor-widget elementor-widget-image\" data-id=\"9a0415c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"93\" height=\"48\" src=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Formel_2.png\" class=\"attachment-large size-large wp-image-6317\" alt=\"\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-04918fe e-flex e-con-boxed e-con e-parent\" data-id=\"04918fe\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3b2c4ae elementor-widget elementor-widget-text-editor\" data-id=\"3b2c4ae\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The rainwater runoff <strong>Q<\/strong> is now calculated from <strong>Q = r * A * C<\/strong>:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1549b8a e-flex e-con-boxed e-con e-parent\" data-id=\"1549b8a\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9c1d3b4 elementor-widget elementor-widget-image\" data-id=\"9c1d3b4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"576\" height=\"114\" src=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Formel_3_korr.jpg\" class=\"attachment-large size-large wp-image-7017\" alt=\"\" srcset=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Formel_3_korr.jpg 576w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Formel_3_korr-300x59.jpg 300w\" sizes=\"(max-width: 576px) 100vw, 576px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-fa390d5 e-flex e-con-boxed e-con e-parent\" data-id=\"fa390d5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-35ab94d elementor-widget elementor-widget-text-editor\" data-id=\"35ab94d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Layout for closed system (individual piping)<\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-38fd1f3 e-flex e-con-boxed e-con e-parent\" data-id=\"38fd1f3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a4599e6 elementor-widget elementor-widget-image\" data-id=\"a4599e6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"531\" src=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb11_Geschlossenes-System_korr.png\" class=\"attachment-large size-large wp-image-7353\" alt=\"\" srcset=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb11_Geschlossenes-System_korr.png 983w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb11_Geschlossenes-System_korr-300x199.png 300w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb11_Geschlossenes-System_korr-768x510.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 11: Schematic for closed system incl. Dimensional data<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-93fe6a5 e-flex e-con-boxed e-con e-parent\" data-id=\"93fe6a5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a0fa189 elementor-widget elementor-widget-spacer\" data-id=\"a0fa189\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c1993d3 elementor-widget elementor-widget-text-editor\" data-id=\"c1993d3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Once the product and the necessary components have been determined, the manufacturer&#8217;s drainage rates are used to select the appropriate components.<\/p><p>A drainage rate of 32.0 l\/s is required for this example. For this reason, three roof drains in DN110 with a capacity of 32,1 l\/s each and an accumulation height of 35 mm are selected (according to the manufacturer&#8217;s drainage table in Figure 9).<\/p><p>The dimension of the roof outlet is selected in accordance with EN 1253, whereby the value with an accumulation height of 35 mm is taken into account for the dimensions DN75 and DN110. For the dimensions DN125 and DN160, on the other hand, the value with an accumulation height of 45 mm is used.<\/p><p>The total capacity of the three roof drains in DN110 is 32,1 l\/s, which exceeds the required value of 32.0 l\/s. Each roof outlet is individually connected to a downpipe with a continuous pipe dimension of DN110.<\/p><p>Note: A schematic diagram of the pipework with the corresponding dimensions must be attached.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-e851fcc e-flex e-con-boxed e-con e-parent\" data-id=\"e851fcc\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-07f15cc elementor-widget elementor-widget-text-editor\" data-id=\"07f15cc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Layout for open systems<\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d49d420 e-flex e-con-boxed e-con e-parent\" data-id=\"d49d420\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-82cc874 elementor-widget elementor-widget-image\" data-id=\"82cc874\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"589\" src=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb12_Offenes-System_korr-1024x754.png\" class=\"attachment-large size-large wp-image-7361\" alt=\"\" srcset=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb12_Offenes-System_korr-1024x754.png 1024w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb12_Offenes-System_korr-300x221.png 300w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb12_Offenes-System_korr-768x565.png 768w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb12_Offenes-System_korr.png 1331w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 12: Schematic for open system incl. Dimensional data<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-49c33d1 e-flex e-con-boxed e-con e-parent\" data-id=\"49c33d1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3ffad41 elementor-widget elementor-widget-spacer\" data-id=\"3ffad41\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-757419f elementor-widget elementor-widget-text-editor\" data-id=\"757419f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>For the open system, the capacity specifications of the roof outlet manufacturer are not decisive for the layout. Instead, the drainage tables in accordance with EN 12056-3 for horizontal base and collection pipes (see Figure 13) and for vertical rainwater downpipes (see Figure 14) should be used.<\/p><p>Planning begins with the required drainage capacity of 32.0 l\/s. Two factors are decisive in determining the required number of roof drains:<\/p><ul><li>The slope of the horizontal pipe &#8211; usually approx. 5 %<\/li><li>The pipe diameter of the drain pipe &#8211; larger diameters enable higher flow rates<\/li><\/ul><p>\u00a0<\/p><p>As the slope is predetermined in most cases, the number of drains and the pipe diameter remain variable. The following options result from the table for our example:<\/p><ul><li>DN100 \u2192 7 drains (5,1 l\/s per drain)<\/li><li>DN125 \u2192 4 drains (8,3 l\/s per drain)<\/li><li>DN150 \u2192 2 drains (15,7 l\/s pro drain)<\/li><\/ul><p>\u00a0<\/p><p>In practice, the variant with <strong>4 drains and DN125 pipes <\/strong>proves to be particularly practical. However, the <strong>final decision lies with the planner<\/strong>, who selects the optimum solution depending on the structural conditions, roof geometry and economic aspects.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f961ec9 e-flex e-con-boxed e-con e-parent\" data-id=\"f961ec9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b082a4c elementor-widget elementor-widget-image\" data-id=\"b082a4c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"635\" height=\"273\" src=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Tabelle_3_EN.png\" class=\"attachment-full size-full wp-image-6584\" alt=\"\" srcset=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Tabelle_3_EN.png 635w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Tabelle_3_EN-300x129.png 300w\" sizes=\"(max-width: 635px) 100vw, 635px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 13: Drainage capacity of horizontal collection and base pipes (EN12056-3)<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-aeb47ac e-flex e-con-boxed e-con e-parent\" data-id=\"aeb47ac\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9a2df37 elementor-widget elementor-widget-spacer\" data-id=\"9a2df37\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fe546ec elementor-widget elementor-widget-text-editor\" data-id=\"fe546ec\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Planning begins with the roof outlet furthest away from the downpipe. The following applies:<\/p><p><strong>Individual <\/strong>connection pipes must always retain the predefined diameter.<\/p><p>Example: If it was decided to use four drains with DN125 as described above, all individual connection pipes must also be DN125.<\/p><p><strong>Horizontal collective connection<\/strong> <strong>pipes<\/strong> must accommodate the entire water volume of the connected roof drains.<\/p><ul><li>As a result, the pipe diameter tends to increase in the direction of flow.<\/li><li>Example (see Figure 12):<ul><li>Between the first and second drain, the collective connection pipe can still be designed in DN125..<\/li><li>After this, an extension to DN150 is required..<\/li><li>In the further course, the pipe must be enlarged to DN200..<\/li><\/ul><\/li><\/ul><p>\u00a0<\/p><p>For the dimensioning of the vertical rainwater downpipe, a filling level of 0.33 must be used in accordance with EN 12056-3, unless national or regional regulations stipulate a different value (see Figure 14).<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a768df5 e-flex e-con-boxed e-con e-parent\" data-id=\"a768df5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-49f2a4f elementor-widget elementor-widget-image\" data-id=\"49f2a4f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"413\" src=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Tabelle_4_EN-1024x528.png\" class=\"attachment-large size-large wp-image-6592\" alt=\"\" srcset=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Tabelle_4_EN-1024x528.png 1024w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Tabelle_4_EN-300x155.png 300w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Tabelle_4_EN-768x396.png 768w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Tabelle_4_EN.png 1080w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 14: Drainage capacity of vertical rainwater downpipes (EN12056-3)<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a915a3e e-flex e-con-boxed e-con e-parent\" data-id=\"a915a3e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-31486d3 elementor-widget elementor-widget-spacer\" data-id=\"31486d3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-56631fc elementor-widget elementor-widget-text-editor\" data-id=\"56631fc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Even if the table from EN 12056-3 (see Figure 14) would allow a smaller pipe diameter here, the diameter of the horizontal collection pipe remains decisive. This means that the downpipe must have at least the diameter of the connected horizontal collection pipe. No reduction of the pipe diameter in the direction of flow is permitted. For our example, this means a pipe diameter of DN200 for the downpipe.<\/p><p>This procedure ensures that the system remains hydraulically efficient and faults are avoided.<\/p><p>The pipe dimensions of the individual sections shown in the pipe diagram (Figure 12) were determined using Figure 13 and Figure 14. Underground pipes or pipes laid under the base plate must also be laid out in accordance with Figure 13.<\/p><h2>Open vs. closed system &#8211; What should be used?<\/h2><p>Which system is ultimately used must be decided by the planner or architect on a case-by-case basis, taking the following aspects into account:<\/p><table><tbody><tr><td width=\"302\"><p><strong>Open system<\/strong> <br \/>(collective piping)<\/p><\/td><td width=\"302\"><p><strong>Closed system<\/strong> <br \/>(individual piping)<\/p><\/td><\/tr><tr><td width=\"302\"><p><strong>Advantages:<\/strong><\/p><ul><li>Less material and labour<\/li><li>Less underground construction work<\/li><\/ul><p>\u00a0<\/p><p><strong>Disadvantages:<\/strong><\/p><ul><li>Less drainage capacity<\/li><li>Dimensioning can only be carried out in accordance to the Tables of the EN12056-3<\/li><\/ul><\/td><td width=\"302\"><p><strong>Advantages<\/strong>:<\/p><ul><li>Compared to an open system, a significantly higher drainage capacity is achieved<\/li><li>The dimensioning and layout of the drain pipe is simple and based exclusively on the drainage values of the roof drains<\/li><li>Generally higher operational reliability when draining rainwater from the roof, as each roof outlet is individually connected to a downpipe and if one pipe section is blocked, all the others remain functional<\/li><\/ul><p>\u00a0<\/p><p><strong>Disadvantages:<\/strong><\/p><ul><li>Higher material and labour costs<\/li><li>The higher number of downpipes requires more underground construction work to lay the base pipe<\/li><\/ul><\/td><\/tr><\/tbody><\/table><h2>Conclusion<\/h2><p>The planning and dimensioning of a roof drainage system requires careful preparation. This includes obtaining all the necessary information in a timely manner, which can sometimes be time-consuming.<\/p><p>Effective rainwater drainage should always be considered as an overall concept &#8211; from the drainage of water from roof and property surfaces to discharge into the public sewer or infiltration on the property. Restrictions imposed by the authorities during heavy rainfall to relieve the sewer network make additional measures such as retention or infiltration necessary and present planners with additional challenges.<\/p><p>Another essential component of safe rainwater drainage is emergency drainage, which ensures that no damage is caused to the building even in the event of exceptionally heavy rainfall (rain of the century). You can find more information about emergency drainage <a href=\"http:\/\/www.hl.at\/upload_cms\/%7B4e43392c-782e-d132-1086-58b3183884c1%7DNotentw%C3%A4sserung_Pro_EN.pdf\" target=\"_blank\" rel=\"noopener\">here<\/a>.<\/p><p><strong>Specification of the roof drain to match the roof construction<br \/><\/strong>For an exact specification of the roof drainage system, the HL support team will be happy to help you at <a href=\"mailto:support@hl.at\">support@hl.at<\/a> or by contacting your <a href=\"https:\/\/www.hutterer-lechner.com\/en\/contacts.aspx\">regional HL sales representative<\/a>. All you have to do is request a sectional drawing with the descriptions of the individual sections from the architect or planner and send it to the HL team. Within a short space of time, you will receive a 3D illustration as well as the detail in various formats in addition to the exact sequence specification:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9cc05a6 e-flex e-con-boxed e-con e-parent\" data-id=\"9cc05a6\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b739f51 elementor-widget elementor-widget-spacer\" data-id=\"b739f51\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1b16e56 e-grid e-con-boxed e-con e-parent\" data-id=\"1b16e56\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c0e916a elementor-widget elementor-widget-image\" data-id=\"c0e916a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"587\" height=\"476\" src=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb13.png\" class=\"attachment-large size-large wp-image-6552\" alt=\"\" srcset=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb13.png 587w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb13-300x243.png 300w\" sizes=\"(max-width: 587px) 100vw, 587px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a56384e elementor-widget elementor-widget-image\" data-id=\"a56384e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"714\" height=\"504\" src=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb14.png\" class=\"attachment-large size-large wp-image-6560\" alt=\"\" srcset=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb14.png 714w, https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Abb14-300x212.png 300w\" sizes=\"(max-width: 714px) 100vw, 714px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-bf96dcc e-flex e-con-boxed e-con e-parent\" data-id=\"bf96dcc\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7bd09d4 elementor-widget elementor-widget-text-editor\" data-id=\"7bd09d4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Relevant standards:<\/h3><p><strong>The following standards apply to the drainage of roofs, balconies and terraces:<\/strong><\/p><ul><li>EN1253-2<\/li><li>EN 12056-3<\/li><li>\u00d6NORM B2501<\/li><\/ul><p>\u00a0<\/p><p><strong>Sources:<\/strong><\/p><ul><li><a href=\"https:\/\/www.austrian-standards.at\/de\/shop\/din-en-1253-1-2015-03~p2123330\">https:\/\/www.austrian-standards.at\/de\/shop\/din-en-1253-1-2015-03~p2123330<\/a><\/li><li><a href=\"https:\/\/www.austrian-standards.at\/de\/shop\/onorm-en-12056-1-2000-12-01~p1339394\">https:\/\/www.austrian-standards.at\/de\/shop\/onorm-en-12056-1-2000-12-01~p1339394<\/a><\/li><li><a href=\"https:\/\/www.austrian-standards.at\/de\/shop\/onorm-b-2501-2025-02-01~p4021532\">https:\/\/www.austrian-standards.at\/de\/shop\/onorm-b-2501-2025-02-01~p4021532<\/a><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>This guide provides a comprehensive introduction to the technical requirements and calculations for the dimensioning of drainage systems for roofs, balconies and terraces. The various drainage solutions and their specific advantages and disadvantages are considered in order to ensure reliable and standard-compliant planning. The aim is to use efficient drainage solutions to prevent water damage and flooding and to ensure the long-term functionality and safety of the building.<\/p>\n","protected":false},"author":10,"featured_media":7085,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[307],"tags":[513,511,510,514,175,308,515,512],"class_list":["post-6960","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-roof-terrace","tag-balcony","tag-balkon-en","tag-dach-en","tag-drainage","tag-entwaesserung-en","tag-roof","tag-terrace","tag-terrasse-en"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.1.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Guidelines for the dimensioning of drainage of roof, balcony and terrace areas - Siphoniker-Blog, HL Hutterer &amp; Lechner GmbH in Himberg<\/title>\n<meta name=\"description\" content=\"This guide provides a comprehensive introduction to the technical requirements and calculations for the dimensioning of drainage systems for roofs, balconies and terraces. The various drainage solutions and their specific advantages and disadvantages are considered in order to ensure reliable and standard-compliant planning. The aim is to use efficient drainage solutions to prevent water damage and flooding and to ensure the long-term functionality and safety of the building.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.siphoniker.at\/en\/guidelines-for-the-dimensioning-of-drainage-of-roof-balcony-and-terrace-areas\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Guidelines for the dimensioning of drainage of roof, balcony and terrace areas - Siphoniker-Blog, HL Hutterer &amp; Lechner GmbH in Himberg\" \/>\n<meta property=\"og:description\" content=\"This guide provides a comprehensive introduction to the technical requirements and calculations for the dimensioning of drainage systems for roofs, balconies and terraces. The various drainage solutions and their specific advantages and disadvantages are considered in order to ensure reliable and standard-compliant planning. The aim is to use efficient drainage solutions to prevent water damage and flooding and to ensure the long-term functionality and safety of the building.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.siphoniker.at\/en\/guidelines-for-the-dimensioning-of-drainage-of-roof-balcony-and-terrace-areas\/\" \/>\n<meta property=\"og:site_name\" content=\"Siphoniker-Blog, HL Hutterer &amp; Lechner GmbH in Himberg\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/huttererlechnergmbh\/\" \/>\n<meta property=\"article:published_time\" content=\"2025-05-27T09:29:23+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-06-05T10:01:16+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Dachablauf_Header-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1440\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"adminHL\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"adminHL\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"14 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.siphoniker.at\/en\/guidelines-for-the-dimensioning-of-drainage-of-roof-balcony-and-terrace-areas\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.siphoniker.at\/en\/guidelines-for-the-dimensioning-of-drainage-of-roof-balcony-and-terrace-areas\/\"},\"author\":{\"name\":\"adminHL\",\"@id\":\"https:\/\/www.siphoniker.at\/en\/#\/schema\/person\/4cc39e8f9338e5ca56ea3c63d0ec178d\"},\"headline\":\"Guidelines for the dimensioning of drainage of roof, balcony and terrace areas\",\"datePublished\":\"2025-05-27T09:29:23+00:00\",\"dateModified\":\"2025-06-05T10:01:16+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.siphoniker.at\/en\/guidelines-for-the-dimensioning-of-drainage-of-roof-balcony-and-terrace-areas\/\"},\"wordCount\":2892,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.siphoniker.at\/en\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.siphoniker.at\/en\/guidelines-for-the-dimensioning-of-drainage-of-roof-balcony-and-terrace-areas\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Dachablauf_Header-scaled.jpg\",\"keywords\":[\"balcony\",\"balkon\",\"Dach\",\"drainage\",\"entw\u00e4sserung\",\"roof\",\"terrace\",\"terrasse\"],\"articleSection\":[\"Roof &amp; Terrace\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.siphoniker.at\/en\/guidelines-for-the-dimensioning-of-drainage-of-roof-balcony-and-terrace-areas\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.siphoniker.at\/en\/guidelines-for-the-dimensioning-of-drainage-of-roof-balcony-and-terrace-areas\/\",\"url\":\"https:\/\/www.siphoniker.at\/en\/guidelines-for-the-dimensioning-of-drainage-of-roof-balcony-and-terrace-areas\/\",\"name\":\"Guidelines for the dimensioning of drainage of roof, balcony and terrace areas - Siphoniker-Blog, HL Hutterer &amp; Lechner GmbH in Himberg\",\"isPartOf\":{\"@id\":\"https:\/\/www.siphoniker.at\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.siphoniker.at\/en\/guidelines-for-the-dimensioning-of-drainage-of-roof-balcony-and-terrace-areas\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.siphoniker.at\/en\/guidelines-for-the-dimensioning-of-drainage-of-roof-balcony-and-terrace-areas\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Dachablauf_Header-scaled.jpg\",\"datePublished\":\"2025-05-27T09:29:23+00:00\",\"dateModified\":\"2025-06-05T10:01:16+00:00\",\"description\":\"This guide provides a comprehensive introduction to the technical requirements and calculations for the dimensioning of drainage systems for roofs, balconies and terraces. The various drainage solutions and their specific advantages and disadvantages are considered in order to ensure reliable and standard-compliant planning. The aim is to use efficient drainage solutions to prevent water damage and flooding and to ensure the long-term functionality and safety of the building.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.siphoniker.at\/en\/guidelines-for-the-dimensioning-of-drainage-of-roof-balcony-and-terrace-areas\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.siphoniker.at\/en\/guidelines-for-the-dimensioning-of-drainage-of-roof-balcony-and-terrace-areas\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.siphoniker.at\/en\/guidelines-for-the-dimensioning-of-drainage-of-roof-balcony-and-terrace-areas\/#primaryimage\",\"url\":\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Dachablauf_Header-scaled.jpg\",\"contentUrl\":\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Dachablauf_Header-scaled.jpg\",\"width\":2560,\"height\":1440},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.siphoniker.at\/en\/guidelines-for-the-dimensioning-of-drainage-of-roof-balcony-and-terrace-areas\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\/\/www.siphoniker.at\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Guidelines for the dimensioning of drainage of roof, balcony and terrace areas\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.siphoniker.at\/en\/#website\",\"url\":\"https:\/\/www.siphoniker.at\/en\/\",\"name\":\"HL Siphoniker-Blog\",\"description\":\"Kompetenz f\u00fcr perfekte Kompositionen - verfasst von Profis f\u00fcr Profis\",\"publisher\":{\"@id\":\"https:\/\/www.siphoniker.at\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.siphoniker.at\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.siphoniker.at\/en\/#organization\",\"name\":\"Hutterer & Lechner GmbH in Himberg\",\"url\":\"https:\/\/www.siphoniker.at\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.siphoniker.at\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2020\/09\/logo-siphoniker-1-1.svg\",\"contentUrl\":\"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2020\/09\/logo-siphoniker-1-1.svg\",\"caption\":\"Hutterer & Lechner GmbH in Himberg\"},\"image\":{\"@id\":\"https:\/\/www.siphoniker.at\/en\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/huttererlechnergmbh\/\",\"https:\/\/www.instagram.com\/hl.hutterer.lechner\/\",\"https:\/\/www.linkedin.com\/company\/hutterer-lechner-gmbh\/\",\"https:\/\/www.youtube.com\/channel\/UCoAza_27xat_FyVQWlmBpqw\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.siphoniker.at\/en\/#\/schema\/person\/4cc39e8f9338e5ca56ea3c63d0ec178d\",\"name\":\"adminHL\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.siphoniker.at\/en\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/20d9c939931b5f8d5caf8f492c355975c1a550b74e3c4a576b229a7cd0f07495?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/20d9c939931b5f8d5caf8f492c355975c1a550b74e3c4a576b229a7cd0f07495?s=96&d=mm&r=g\",\"caption\":\"adminHL\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Guidelines for the dimensioning of drainage of roof, balcony and terrace areas - Siphoniker-Blog, HL Hutterer &amp; Lechner GmbH in Himberg","description":"This guide provides a comprehensive introduction to the technical requirements and calculations for the dimensioning of drainage systems for roofs, balconies and terraces. The various drainage solutions and their specific advantages and disadvantages are considered in order to ensure reliable and standard-compliant planning. The aim is to use efficient drainage solutions to prevent water damage and flooding and to ensure the long-term functionality and safety of the building.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.siphoniker.at\/en\/guidelines-for-the-dimensioning-of-drainage-of-roof-balcony-and-terrace-areas\/","og_locale":"en_US","og_type":"article","og_title":"Guidelines for the dimensioning of drainage of roof, balcony and terrace areas - Siphoniker-Blog, HL Hutterer &amp; Lechner GmbH in Himberg","og_description":"This guide provides a comprehensive introduction to the technical requirements and calculations for the dimensioning of drainage systems for roofs, balconies and terraces. The various drainage solutions and their specific advantages and disadvantages are considered in order to ensure reliable and standard-compliant planning. The aim is to use efficient drainage solutions to prevent water damage and flooding and to ensure the long-term functionality and safety of the building.","og_url":"https:\/\/www.siphoniker.at\/en\/guidelines-for-the-dimensioning-of-drainage-of-roof-balcony-and-terrace-areas\/","og_site_name":"Siphoniker-Blog, HL Hutterer &amp; Lechner GmbH in Himberg","article_publisher":"https:\/\/www.facebook.com\/huttererlechnergmbh\/","article_published_time":"2025-05-27T09:29:23+00:00","article_modified_time":"2025-06-05T10:01:16+00:00","og_image":[{"width":2560,"height":1440,"url":"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Dachablauf_Header-scaled.jpg","type":"image\/jpeg"}],"author":"adminHL","twitter_card":"summary_large_image","twitter_misc":{"Written by":"adminHL","Est. reading time":"14 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.siphoniker.at\/en\/guidelines-for-the-dimensioning-of-drainage-of-roof-balcony-and-terrace-areas\/#article","isPartOf":{"@id":"https:\/\/www.siphoniker.at\/en\/guidelines-for-the-dimensioning-of-drainage-of-roof-balcony-and-terrace-areas\/"},"author":{"name":"adminHL","@id":"https:\/\/www.siphoniker.at\/en\/#\/schema\/person\/4cc39e8f9338e5ca56ea3c63d0ec178d"},"headline":"Guidelines for the dimensioning of drainage of roof, balcony and terrace areas","datePublished":"2025-05-27T09:29:23+00:00","dateModified":"2025-06-05T10:01:16+00:00","mainEntityOfPage":{"@id":"https:\/\/www.siphoniker.at\/en\/guidelines-for-the-dimensioning-of-drainage-of-roof-balcony-and-terrace-areas\/"},"wordCount":2892,"commentCount":0,"publisher":{"@id":"https:\/\/www.siphoniker.at\/en\/#organization"},"image":{"@id":"https:\/\/www.siphoniker.at\/en\/guidelines-for-the-dimensioning-of-drainage-of-roof-balcony-and-terrace-areas\/#primaryimage"},"thumbnailUrl":"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Dachablauf_Header-scaled.jpg","keywords":["balcony","balkon","Dach","drainage","entw\u00e4sserung","roof","terrace","terrasse"],"articleSection":["Roof &amp; Terrace"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.siphoniker.at\/en\/guidelines-for-the-dimensioning-of-drainage-of-roof-balcony-and-terrace-areas\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.siphoniker.at\/en\/guidelines-for-the-dimensioning-of-drainage-of-roof-balcony-and-terrace-areas\/","url":"https:\/\/www.siphoniker.at\/en\/guidelines-for-the-dimensioning-of-drainage-of-roof-balcony-and-terrace-areas\/","name":"Guidelines for the dimensioning of drainage of roof, balcony and terrace areas - Siphoniker-Blog, HL Hutterer &amp; Lechner GmbH in Himberg","isPartOf":{"@id":"https:\/\/www.siphoniker.at\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.siphoniker.at\/en\/guidelines-for-the-dimensioning-of-drainage-of-roof-balcony-and-terrace-areas\/#primaryimage"},"image":{"@id":"https:\/\/www.siphoniker.at\/en\/guidelines-for-the-dimensioning-of-drainage-of-roof-balcony-and-terrace-areas\/#primaryimage"},"thumbnailUrl":"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Dachablauf_Header-scaled.jpg","datePublished":"2025-05-27T09:29:23+00:00","dateModified":"2025-06-05T10:01:16+00:00","description":"This guide provides a comprehensive introduction to the technical requirements and calculations for the dimensioning of drainage systems for roofs, balconies and terraces. The various drainage solutions and their specific advantages and disadvantages are considered in order to ensure reliable and standard-compliant planning. The aim is to use efficient drainage solutions to prevent water damage and flooding and to ensure the long-term functionality and safety of the building.","breadcrumb":{"@id":"https:\/\/www.siphoniker.at\/en\/guidelines-for-the-dimensioning-of-drainage-of-roof-balcony-and-terrace-areas\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.siphoniker.at\/en\/guidelines-for-the-dimensioning-of-drainage-of-roof-balcony-and-terrace-areas\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.siphoniker.at\/en\/guidelines-for-the-dimensioning-of-drainage-of-roof-balcony-and-terrace-areas\/#primaryimage","url":"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Dachablauf_Header-scaled.jpg","contentUrl":"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2025\/05\/Dachablauf_Header-scaled.jpg","width":2560,"height":1440},{"@type":"BreadcrumbList","@id":"https:\/\/www.siphoniker.at\/en\/guidelines-for-the-dimensioning-of-drainage-of-roof-balcony-and-terrace-areas\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/www.siphoniker.at\/en\/"},{"@type":"ListItem","position":2,"name":"Guidelines for the dimensioning of drainage of roof, balcony and terrace areas"}]},{"@type":"WebSite","@id":"https:\/\/www.siphoniker.at\/en\/#website","url":"https:\/\/www.siphoniker.at\/en\/","name":"HL Siphoniker-Blog","description":"Kompetenz f\u00fcr perfekte Kompositionen - verfasst von Profis f\u00fcr Profis","publisher":{"@id":"https:\/\/www.siphoniker.at\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.siphoniker.at\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.siphoniker.at\/en\/#organization","name":"Hutterer & Lechner GmbH in Himberg","url":"https:\/\/www.siphoniker.at\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.siphoniker.at\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2020\/09\/logo-siphoniker-1-1.svg","contentUrl":"https:\/\/www.siphoniker.at\/wp-content\/uploads\/2020\/09\/logo-siphoniker-1-1.svg","caption":"Hutterer & Lechner GmbH in Himberg"},"image":{"@id":"https:\/\/www.siphoniker.at\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/huttererlechnergmbh\/","https:\/\/www.instagram.com\/hl.hutterer.lechner\/","https:\/\/www.linkedin.com\/company\/hutterer-lechner-gmbh\/","https:\/\/www.youtube.com\/channel\/UCoAza_27xat_FyVQWlmBpqw"]},{"@type":"Person","@id":"https:\/\/www.siphoniker.at\/en\/#\/schema\/person\/4cc39e8f9338e5ca56ea3c63d0ec178d","name":"adminHL","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.siphoniker.at\/en\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/20d9c939931b5f8d5caf8f492c355975c1a550b74e3c4a576b229a7cd0f07495?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/20d9c939931b5f8d5caf8f492c355975c1a550b74e3c4a576b229a7cd0f07495?s=96&d=mm&r=g","caption":"adminHL"}}]}},"_links":{"self":[{"href":"https:\/\/www.siphoniker.at\/en\/wp-json\/wp\/v2\/posts\/6960","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.siphoniker.at\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.siphoniker.at\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.siphoniker.at\/en\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/www.siphoniker.at\/en\/wp-json\/wp\/v2\/comments?post=6960"}],"version-history":[{"count":7,"href":"https:\/\/www.siphoniker.at\/en\/wp-json\/wp\/v2\/posts\/6960\/revisions"}],"predecessor-version":[{"id":7496,"href":"https:\/\/www.siphoniker.at\/en\/wp-json\/wp\/v2\/posts\/6960\/revisions\/7496"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.siphoniker.at\/en\/wp-json\/wp\/v2\/media\/7085"}],"wp:attachment":[{"href":"https:\/\/www.siphoniker.at\/en\/wp-json\/wp\/v2\/media?parent=6960"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.siphoniker.at\/en\/wp-json\/wp\/v2\/categories?post=6960"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.siphoniker.at\/en\/wp-json\/wp\/v2\/tags?post=6960"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}